Amada Pega 357 User Manual Work
Overview — Amada Pega 357 User Manual
Manual Answer:
Locate the hydraulic manifold block behind the left access door. Press the red "Reset" button on the pressure switch (Siemens or Telemecanique brand) for 5 seconds. Then jog the ram down 0.1" in manual mode. Never force the reset if the ram is jammed on a tool.
- Axis drive alarms (X, Y, Turret, Auto-index).
- Power supply faults.
- Limit switch logic.
Per the manual, a ½" diameter punch in a "D" station cannot exceed 22 tons. Overloading (e.g., punching ½" thick stainless steel with a small punch) will crack the turret casting. The manual provides a full tonnage chart based on material type, thickness, and punch diameter. amada pega 357 user manual